Installer-Programmable Features
To access the installer-programmable features, use the procedure defined in the User-Programmable s ection, but after completing
step 4, continue to press and hold the ✱ side of the PlainView 2 Switch for another 10 seconds. You will hear three confirmation
chirps indicating that the system is in installer-program mode.
Table of Installer-Programmable Features: 1 chirp = OFF, 2 chirps = ON.
Fea ture
Select
Unmarked 1 Unmarked 2 Unmarked 3
✱ 1
Single/Double Lock Pulse
(1 chirp/2 chirps)
Accessory Output Timer
Duration
(10 Seconds)
NOTE 1
Door Ajar Warning /Delayed
Courtesy Lights
(1 chirp /2 chirps)
✱ 2
Single /Double Unlock Pulse
(1 chirp/2 chirps)
Auxiliary A type
(Pulsed /Timed/Latched)
(1 chirp /2 chirps/3 chirps)
Auxiliary A Interlock
(On/Off)
✱ 3
Lock/Unlock Pulse
1 second/3 second
(1 chirp/2 chirps)
Auxiliary B type
(Pulsed /Timed/Latched)
(1 chirp/2 chirps/3 chirps)
Auxiliary B Interlock
On/Off
✱ 4
Door Lock Polarity
Positive/Negative
(1 chirp/2 chirps)
Diesel Engine /Petrol Engine
(1 chirp/2 chirps)
(Requires Optional
IntelliStart 4)
NOTE 2
AutoActivate Auxiliary B
(On/Off)
✱ 5
Program RPM (Requires Optional
IntelliStart 4)
Program Optional
SmartWindows 4 or Learn
PageMate 4 ID
NOT USED
NOTE 1: Once this feature is selected, you will hear one chirp to confirm that the timer has started. You can set this anywhere from
one to 4.25 minutes (255 seconds). When the desired duration has been reached, press the unmarked side of the PlainView 2 switch.
You will hear two chirps to confirm the new system timer duration.
NOTE 2: After programming either petrol or diesel, you must perform the mandatory RPM programming.
System Checklist & Troubleshooting
The fol low ing check list and trou ble shoot ing tips will as sure that you have in stalled the Co ncept 100 cor rectly. If the sys tem does not
re act as noted, fol low the trou ble shoot ing tip(s) de noted with a black box be low that item, then re peat the step. Each suc ces sive step
re quires that the pre vious step has been com pleted as in di cated.
Step 1.
Re-enable the courtesy lights.
In step 1 of the Important Information sec tion (the first tabbed section) in this binder, the in te rior cour tesy lights were disabled.
You must now re-enable the courtesy lights by re placing the fuse you re moved or re set the cour t esy light switch back to its nor mal
“DOOR” po si tion bef ore pro ceed ing.
Step 2.
Test the Im mo bi li sa tion cir cuit.
n
Arm the Concept 100 (either from inside or outside the vehicle) and wait 10 seconds. Turn the ignit ion to the “ON” position.
o Engine does not respond and alarm triggers. This is the correct response, proceed to step 3.
o Engine starts or cranks. The starter im mo bi li sa tion cir cuit has been mis wired. Care fully re test the ve hi cle wires as noted
in the Starter and Ignition Immo bi li sa tion Cir cuit section on page 5.
o Engine still starts or cranks after retesting all the wiring as noted on page 5, check the power and ground connections.
Then make sure the fuses are in the fuseholders, verify the control unit connectors are securely fa stened, verify the ignition
wires are connected to the true ignition line instead of a 12V or accessory line, and verify that t he transmitters are
programmed correctly.